ETC Request ID: STIS.sp.1003056

Exposure time (seconds) = 2,026.0000 at wavelength 1549.00 Å

gives: SNR = 15.1176 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.057 232.72 15.26
    Background 0.001 4.25 2.06
        Sky 5.136e-11 2.08e-07 4.56e-04
        Dark Current 0.001 4.25 2.06
Total in selected region 0.058 236.98 15.39
Brightest Pixel (single exposure) (at 1215.90 Å) 2.930 5,937.15
Count rate entire detector 327.286

Buffer Time (sec) 6,110.86
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 56.848 115,173.932
    Background (sky+dark) 270.438 547,908.05

Encircled energy fraction 0.84


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength:
Grating: [G140L] R ~ 1000
Aperture: 52X0.2
Glow region: low


Target: [point source]
Spectrum: User uploaded spectrum: CD35-2722_full_scaled.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2